Transportation Safety Board of Canada
www.bst-tsb.gc.ca
REPORTS > AVIATION > 2002 > A02O0123
Table of Contents
- 1.0 Factual Information
- 1.1 History of the Flight
- 1.2 Injuries to Persons
- 1.3 Damage to Aircraft
- 1.4 Personnel Information
- 1.5 Aircraft Information
- 1.5.1 General
- 1.5.2 Aircraft History
- 1.5.3 Aft Cargo Compartment
- 1.5.4 Fire Extinguishing System
- 1.5.5 Water Line Heating System
- 1.5.5.1 Description
- 1.5.5.2 Water Line Repair
- 1.5.6 Thermal Acoustic Insulation
- 1.6 Notification and Flight Recorders
- 1.6.1 Notification of the Occurrence
- 1.6.2 Data Retention
- 1.7 Medical Information
- 1.8 Fire
- 1.9 Survival Aspects
- 1.10 Additional Information
- 1.10.1 Heater Ribbon Failures
- 1.10.1.1 History
- 1.10.1.2 Additional Heater Ribbon Failures on C-GHML
- 1.10.1.3 Heater Ribbon Failures on Other Air Canada Aircraft
- 1.10.2 Insulation Blanket Contamination
- 1.10.2.1 History
- 1.10.2.2 Insulation Blanket Condition on C-GHML
- 1.10.2.3 Insulation Blanket Contamination on Other Air Canada Aircraft
- 1.10.3 Circuit Protection Devices
- 1.10.4 Material Flammability Standards
- 1.10.4.1 Development
- 1.10.4.2 Testing Procedures
- 1.10.5 Certification of Imported Aircraft
- 2.0 Analysis
- 2.1 General
- 2.2 Ignition
- 2.3 Contamination
- 2.4 Drain Line Repair
- 2.5 Certification
- 2.6 Notification and Data Preservation
- 3.0 Conclusions
- 3.1 Findings as to Causes and Contributing Factors
- 3.2 Findings as to Risk
- 3.3 Other Findings
- 4.0 Safety Action
- 4.1 Action Taken
- 4.1.1 Air Canada
- 4.1.2 Boeing
- 4.1.3 Transportation Safety Board of Canada
- 4.1.4 Federal Aviation Administration
- 4.1.5 Transport Canada
- 4.2 Safety Concerns
- 5.0 Appendices
- Appendix A - List of Supporting Reports
- Appendix B - Glossary
- Figures
- Figure 1 - Fire Location
- Photos
- Photo 1 - Fire-damaged Area
- Photo 2 - Aft Cargo Compartment
- Photo 3 - Fire-damaged Area
- Photo 4 - Contaminated Insulation Blankets and Debris
- Photo 5 - Burned Heater Ribbon Behind Aft Wall
- Photo 6 - Dust and Lint Accumulation on Wiring Bundles Behind Wall Panel
- Photo 7 - Dust and Lint Accumulation on Thermal Acoustic Insulation Behind Wall Panel
Previous | Next